Features of Class II Biosafety Cabinet:
1. Operations on three sides and side wall panels unibody structure, leave some space
at the bottom, easy to clean, to avoid cross infection.
2. Front window: when using optical perspective is clear, clean and disinfect does not negatively
impact burst-proof tempered glass, tempered glass production, glass thickness ≥ 5 mm.
3. Cabinet: four two-tier structure, all Studio and the collecting tank to use imports 304 stainless
steel materials.
4. Blower/motor maintenance and disassembly, replacement HEPA filters are available from all
safety cabinets.
5. Containment of the Cabinet: the cabinets pressurized to 500Pa, keep the air pressure
is not lower than 450Pa after 30min.
6. Cabinet stability: a countertop Center load 23kg unload, countertop must not bend downward.
7. Alarm system: safety Cabinet front window opening height exceeds a set level, decreased
safety Cabinet flow velocity and flow fluctuation of air flow velocity in excess of their nominal
value of 20%, the interlocking system startup, sound, light, sound and alarm.
8. HEPA filter integrity: scan filter at any point of the leak rate of less than 0.01%.
9. Cannot scan filters detect leak rate of less than 0.005% personal protection: percussive sampler
number ≤ 10CFU/.
10. Slit type sampler number ≤ 5CFU/product protection: colony count ≤ 5CFU/cross
infection: colony count ≤ 2CFU/.
Technical Parameters of Class II Biosafety Cabinet:
Product name |
Class II Biosafety Cabinet |
||
Index/type technical parameter |
HZJBSC-1100-LⅡA2 |
HZJBSC-1360-LⅡA2 |
HZJBSC-1800IIA2 |
Exhaust volume |
30% exhaust |
||
HEPA filter leakage ratio |
≤0.005% |
||
Wind speed |
Inflows flow average wind speed: >0.5M/s Downdrafts in average wind speed: 0.25-0.5 m/s |
||
Noise |
≤62dB(A) |
||
Semi-peak |
≤3μm(rms) |
||
Illumination |
≥700LX |
||
Display |
LCD + remote control |
||
Power supply |
Single AC 220V/50Hz |
||
Normal power consumption |
0.85kw |
||
Max power consumption |
1.85kw (including two spare socket 1000W) |
||
Weight |
305kg |
320kg |
326kg |
Workspace dimensions |
1220x600x680mm |
1360x600x680mm |
1800x600x680mm |
Device overall dimension |
1382x790x2150mm |
1525x790x2150mm |
1940x790x2150mm |
Air filter specifications and quantity |
1215x500x50mmx① |
1355x500x50mmx① |
1795x500x50mmx① |
Exhaust air filter specifications and quantity |
600x440x90mmx① |
740x400x90mmx① |
865x440x90mmx① |
Fluorescent lights/UV lamps specifications and quantity |
30w×②/30w×① |
40w×②/40w×① |
40w×②/40w×① |
The number of applicable |
Single double single |
Double single |
More than single-sided |